The Pulses Per Revolution (PPR) for a servo motor refers to the number of electrical pulse signals required for the motor to complete one full rotation. This is a critical parameter for controlling the motor's rotational accuracy. In the drive's manual, this parameter is listed as C00.02, with a default value of 10000.
The value of C00.02 can be modified using any of the following three methods:
Using the Configuration Software
- Click Parameter Management.
- Click C00 Group Parameters.
- Check the box for C00.02 and enter your desired value in the setting field.
- Click Write Selected.
Finally, cycle power to the drive (turn it off and back on) for the change to take effect.
Modifying via Modbus RTU Command (RS-485)
The corresponding Modbus register address for C00.02 is 0002. Send the following command:
01 06 00 02 xx xx CRC CRC
Where xx xx represents the hexadecimal value of the desired number. For example, 5000 in hexadecimal is 13 88. The CRC CRC bytes are the Modbus CRC-16 checksum, which must be calculated based on the preceding bytes. Refer to the Modbus RTU specification or use the configuration software to generate the complete command.
Note: Ensure the servo is disabled (motor de-energized) before modifying this parameter. To save parameters permanently to the drive's non-volatile memory, send the save command after writing the new value:
01 06 0A 05 00 01 CRC CRC
Modifying via the Drive Panel Buttons
After powering on the drive, when the panel defaults to displaying P-rd, proceed as follows:
- Press the
MODEbutton once. The panel will displayC00.blinking.

- Press the
SETbutton again. The panel will displayC00.00blinking, indicating the current parameter being set is C00.00.

- Press the
UPbutton twice to increase the value; the panel will displayC00.02.

- Press the
SETbutton again. The panel will now display the lower four digits of the C00.02 value. For values exceeding 9999, you must also set the higher-order digits. Refer to page 182 of the manual for details on navigating between the high, middle, and low digit groups.

- Use the
UPandDOWNbuttons to adjust the value.

- After setting the value, press the
SETbutton to confirm.

Finally, cycle power to the drive (turn it off and back on) for the change to take effect.